Najiba F. Salih, Mohammed F. Sabri, Amera G. Baker

Last modified: 2018-08-16

Abstract


The present study was performed to determine the concentration of radon (222Rn) in the urine samples for human by using PM-355 detector with PVC tube. This study was carried out on 30 urine samples from 30 persons of different ages (between 20-48 years) and they all have diabetes problems. The result showed that the highest concentration and the highest annual effect dose in 30 ml of urine samples were about 33.650 Bq/L, and 0.8479 mSvy-1, respectively, for the S19 (48 years). However, the lowest concentration and the lowest annual effect dose were about 10.285 Bq/L and 0.2591 mSvy-1, respectively, for the S23 (20 years). In addition, the results showed that the concentration of radon gas was varied from person to another, depending on the allergy of that person to the radiation. The average absorption dose in this study was 0.3963 mSvy-1, which is quite below the range (3-10 mSvy-1) that was reported by the ICRP, therefore, there is no evidence of health problems and no evidence of the relationship between radiation and diabetes. Generally, the obtained results were lower than the normal levels.

 

Published 01 August 2018

DOI: 10.14500/icpas2018.nus46

http://dx.doi.org/10.14500/icpas2018.nus46

 


Keywords


Alpha particle; PM-355, Radiation; Radon concentration; Urine